160-6 dipole #3            
Tested at 33 foot center ends at aprox. 20 foot L config      
Hot N/S   Ground E/W            
12 AWG Wire     Length 99' (Coated 2 conductor)  
300 ohm Ladder Line    Length 30' (window type Strand wire)
130 ft RG8u coax              
               
Results without a tuner on a TS-2000 Rx/Xs readings with MFJ 269 Analyzer  
160m SWR Rs Xs   15m SWR Rs Xs
1.800 5.9 10 36   21.000 2.8 27 29
1.900 4.1 14 41   21.225 2.9 29 39
2.000 4.2 10 46   21.450 3 71 71
               
               
80m SWR Rs Xs   12m SWR Rs Xs
3.500 4.3 9 14   24.890 1.7 87 12
3.750 2.8 40 54   24.940 1.8 90 13
4.000 4.5 42 85   24.990 1.9 93 17
               
               
60m SWR Rs Xs   10m SWR Rs Xs
5.330.5 5.8 5 64   28.000 2.9 116 60
5.366.5 5.8 5 69   28.800 2.8 21 23
5.403.5 5.9 6 74   29.700 2.7 23 27
               
               
40m SWR Rs Xs   6m SWR Rs Xs
7.000 2.4 23 17   50.000 2.2 86 46
7.175 2.1 42 37   52.000 1.8 57 30
7.300 2.1 78 41   54.000 1.9 27 11
               
               
30m SWR Rs Xs   2m SWR Rs Xs
10.100 5.2 14 46   144.000 1.5 50 20
10.125 5.2 14 44   146.000 1.4 67 15
10.150 5.0 14 41   148.000 1.2 41 6
               
               
20m SWR Rs Xs   70cm SWR Rs Xs
14.000 1.9 29 17   420.000 1.4 N/A N/A
14.175 1.6 37 17   435.000 1.6 N/A N/A
14.350 1.7 35 17   450.000 1.6 N/A N/A
               
        Tuned all available bands on TS-2000 with
17m SWR Rs Xs   the internal tuner at this test configuration.
18.068 3.4 162 54          
18.130 3.3 159 54          
18.168 3.3 147 62